

Bently Nevada 288055-01 3500/22M Standard Transient Data Interface Module
The Bently Nevada 288055-01 is a cpu module for Bently Nevada platforms. 10Base-T / 100Base-TX I/O: 10Base-T or 100Base-TX Ethernet, autosensing | 100Base-FX I/O: 100Base-FX Fiber-Optic Ethernet | Operating Temperature: -30 °C to +65 °C (-22 °F to +149 °F). Factory-sealed, live-rack tested, 48-hour burn-in. 12-month warranty. Ships within 24 hours.
Technical Specifications
| Power Consumption | 10.5 Watts |
|---|---|
| Front Panel | 115.2 kbaud maximum RS232 serial communications |
| 10Base-T / 100Base-TX I/O | 10Base-T or 100Base-TX Ethernet, autosensing |
| 100Base-FX I/O | 100Base-FX Fiber-Optic Ethernet |
| Operating Temperature | -30 °C to +65 °C (-22 °F to +149 °F) |
| Storage Temperature | -40 °C to +85 °C (-40 °F to +185 °F) |
| Humidity | 95%, non-condensing |
| Powered TDI | 38 years @ 50°C (122 °F) |
| Un-powered TDI | 12 years @ 50°C (122 °F) |
| North American Approval Option (01) | Class 1, Div 2, Groups A, B, C, D, T4 @ Ta = -20 °C to +65 ºC (-4 ºF to +150 ºF) |
| North American Approval Option (02) | Ex nC[L] IIC, Class 1, Zone 2, Class 1, Div 2, Groups A, B, C, D, T4 @ Ta = -20 °C to +65 ºC (-4 ºF to +150 ºF) |
| ATEX Approval Option (02) | II 3/(3) G, Ex nC[L] IIC, T4 @ Ta = -20 °C to +65 ºC (-4 ºF to +150 ºF) |
| TDI Module Dimensions (Height x Width x Depth) | 241.3 mm x 24.4 mm x 241.8 mm (9.50 in x 0.96 in x 9.52 in) |
| Weight | 0.91 kg (2.0 lbs) |
| Manufacturer | Bently Nevada |
| Model / SKU | 288055-01 |
Ships within 24 hours | 12-Month Warranty | Worldwide Delivery
When to Replace a Bently Nevada Power Supply — Before It Fails
Power supply degradation is gradual, and the warning signs are subtle: the module runs warmer than it used to, output voltage drifts toward the low end of the acceptable range, or the system logs occasional power-quality events that were not there six months ago. By the time the power supply actually trips offline, the degradation has been underway for months.
The Bently Nevada 288055-01 is a direct replacement for your existing power supply module. We test every unit under load on a live Bently Nevada chassis before shipping — all output rails verified at nominal and peak current, ripple within specification, 48-hour continuous operation at elevated temperature to catch infant mortality. A printed test report accompanies every shipment.
For critical systems, we recommend N+1 power supply redundancy where the chassis supports it. If your rack accepts dual power supplies (many Bently Nevada systems do), install both. That way, a single power supply failure is a non-event — the secondary supply carries the load, the system logs a warning, and you replace the failed unit during the next maintenance window. We stock Bently Nevada power supplies for immediate shipment. 12-month warranty.
Compatible Parts — Same System
These modules share the same system family as the 288055-01. Commonly ordered together for complete rack builds or spare parts kits.
Related Products