Bently Nevada 9200-01-05-10-00 Two-Wire Velocity Seismoprobe Transducer
Downtime is expensive. The 9200-01-05-10-00 two-wire transducer pays for itself the first time you need it. Product Type: Two-Wire Transducer | Made in: U.S.A | Model: 9200 = Two-Wire Seismoprobe Velocity Transducer. Factory-new, bench-tested, 12-month replacement warranty.
Technical Specifications
| Manufacturer | Bently Nevada |
|---|---|
| Product No. | 9200-01-05-10-00 |
| Product Type | Two-Wire Transducer |
| Made in | U.S.A |
| Model | 9200 = Two-Wire Seismoprobe Velocity Transducer |
| Transducer Mounting Angle/Minimum Operating | 01 - 0 ±2.5°, 4.5 Hz (270 cpm) |
| Connector Option | 05 = Terminal block top mount |
| Mounting Base Option | 10 = Circular; M10x1 stud |
| Agency Approval Option | 00 = No approvals required |
| Shipping Weight | 2 kg |
| Model / SKU | 9200-01-05-10-00 |
Ships within 24 hours | 12-Month Warranty | Worldwide Delivery
Why the Bently Nevada 9200-01-05-10-00 Matters for Your Operation
In power generation, every component in your control system has a specific job — and when one fails, the ripple effects can shut down an entire production line. The Bently Nevada 9200-01-05-10-00 is a two-wire transducer that keeps your gas turbine control systems and steam turbine monitoring running without interruption.
Here is what this module actually does. manufacturer: Bently Nevada; product no.: 9200-01-05-10-00; product type: Two-Wire Transducer; made in: U.S.A. These are not generic specifications — they determine whether this module will work in your specific Bently Nevada system. We have seen too many cases where a maintenance team ordered a replacement only to find it was the wrong revision or configuration. That is why we test every 9200-01-05-10-00 on a live Bently Nevada rack before shipping — full signal injection across every channel, not just a visual check.
Installation matters too. The most common cause of DOA reports is not a defective module — it is bent backplane pins from forcing a module in at the wrong angle. Take your time lining up the guides. Apply even pressure. If it does not slide in smoothly, stop and check the alignment. Always wear a grounded wrist strap — static discharge from removing a fleece jacket in a dry turbine hall can exceed 15,000 volts, destroying sensitive input protection diodes instantly.
Think about your sparing strategy. A single Bently Nevada 9200-01-05-10-00 costs a fraction of what one hour of unplanned downtime costs in power generation. We ship replacements within 24 hours from Shenzhen — but even 24 hours is too long if you are losing production. For critical applications, keep one cold spare on your shelf.
Compatible Parts — Same System
These modules share the same system family as the 9200-01-05-10-00. Commonly ordered together for complete rack builds or spare parts kits.
Related Products