HIMA

HIMA Cabinet K9203A Industrial Rack Fan Brand New

SKU: K9203A In Stock
FanHIMARack Fan

Automation does not wait. The HIMA K9203A is a rack fan in our Shenzhen warehouse right now. Air Flow: 300 m3 per hour | Rated Speed: 2800 min-1 (revolutions per minute) | Sound Pressure Level: Approximately 55 dB(A). Verified before packing. 12-month warranty.

Technical Specifications

Product NameK 9203A Rack Fan
Operating Data24 VDC, -15…+20 %, ripple ≤ 15 %, max. 750 mA
Air Flow300 m3 per hour
Rated Speed2800 min-1 (revolutions per minute)
Sound Pressure LevelApproximately 55 dB(A)
Lifetime at 40 °C62,500 hours
Space Requirement19”, 1 RU (rack unit), depth 215 mm
Weight1.8 kg
Ambient Temperature-20…+70 ºC
ManufacturerHIMA
Model / SKUK9203A
Request a Quote — K9203A

Ships within 24 hours  |  12-Month Warranty  |  Worldwide Delivery

Category: racks backplanes terminalactive productssafety systemshima other serieshima himatrixfactory newvoltage 24vdctemp standard temphimaall
Filter by Specification:

Why the HIMA K9203A Matters for Your Operation

In power generation, every component in your control system has a specific job — and when one fails, the ripple effects can shut down an entire production line. The HIMA K9203A is a rack fan that keeps your gas turbine control systems and steam turbine monitoring running without interruption.

Here is what this module actually does. product name: K 9203A Rack Fan; operating data: 24 VDC, -15…+20 %, ripple ≤ 15 %, max. 750 mA; air flow: 300 m3 per hour; rated speed: 2800 min-1 (revolutions per minute). These are not generic specifications — they determine whether this module will work in your specific HIMA system. We have seen too many cases where a maintenance team ordered a replacement only to find it was the wrong revision or configuration. That is why we test every K9203A on a live HIMA rack before shipping — full signal injection across every channel, not just a visual check.

Installation matters too. The most common cause of DOA reports is not a defective module — it is bent backplane pins from forcing a module in at the wrong angle. Take your time lining up the guides. Apply even pressure. If it does not slide in smoothly, stop and check the alignment. Always wear a grounded wrist strap — static discharge from removing a fleece jacket in a dry turbine hall can exceed 15,000 volts, destroying sensitive input protection diodes instantly.

Think about your sparing strategy. A single HIMA K9203A costs a fraction of what one hour of unplanned downtime costs in power generation. We ship replacements within 24 hours from Shenzhen — but even 24 hours is too long if you are losing production. For critical applications, keep one cold spare on your shelf.

Compatible Parts — Same System

These modules share the same system family as the K9203A. Commonly ordered together for complete rack builds or spare parts kits.

Bently Nevada 125840-01 Bently Nevada 125840-01 High Voltage ac Power Input  Module (PIM) — replacement industrial module
Bently Nevada
Bently Nevada 125840-01 High Voltage ac Power Input Module (PIM)
125840-01
Bently Nevada 125840-02 Bently Nevada | 125840-02 | 3500/15 | Low Voltage ac Power Input  Module (PIM) — replacement industrial module
Bently Nevada
Bently Nevada | 125840-02 | 3500/15 | Low Voltage ac Power Input Module (PIM)
125840-02
Bently Nevada 133292-01 Bently Nevada 133292-01 3500/15 Low Voltage dc Power Supply Module — replacement industrial module
Bently Nevada
Bently Nevada 133292-01 3500/15 Low Voltage dc Power Supply Module
133292-01
Bently Nevada 133300-01 Bently Nevada 3500/15 133300-01 Low Voltage dc Power Input Module (PIM) — replacement industrial module
Bently Nevada
Bently Nevada 3500/15 133300-01 Low Voltage dc Power Input Module (PIM)
133300-01
Bently Nevada 129478-01 Bently Nevada 3500/15 129478-01 High Voltage dc Power Input  Module (PIM) — replacement industrial module
Bently Nevada
Bently Nevada 3500/15 129478-01 High Voltage dc Power Input Module (PIM)
129478-01
Bently Nevada 106M1079-01 Bently Nevada | 3500/15 | 106M1079-01 | Universal AC Power Supply Module — replacement industrial module
Bently Nevada
Bently Nevada | 3500/15 | 106M1079-01 | Universal AC Power Supply Module
106M1079-01
Bently Nevada 106M1081-01 Bently Nevada | 3500/15 | 106M1081-01 | Universal AC Power Input Module — replacement industrial module
Bently Nevada
Bently Nevada | 3500/15 | 106M1081-01 | Universal AC Power Input Module
106M1081-01
Bently Nevada 125744-02 Bently Nevada 125744-02 3500/20 Standard Rack Interface Module — replacement industrial module
Bently Nevada
Bently Nevada 125744-02 3500/20 Standard Rack Interface Module
125744-02

Related Products

Bently Nevada 125744-01 Bently Nevada 125744-01 3500/20 TMR Rack Interface Module — replacement industrial module
Bently Nevada
SKU: 125744-01
In Stock
Bently Nevada 125760-01 Bently Nevada 3500/20 125760-01 Data Manager I/O Module — replacement industrial module
Bently Nevada
SKU: 125760-01
In Stock
Bently Nevada 126648-02 126632-01 | Bently Nevada | TMR I/O Module — replacement industrial module
Bently Nevada
SKU: 126648-02
In Stock
Bently Nevada 125388-01 Bently Nevada 3500/25 125388-01 Half-height Chassis — replacement industrial module
Bently Nevada
SKU: 125388-01
In Stock
Bently Nevada 125712-01 Bently Nevada 3500/32 125712-01 Spare 4-Channel Relay Module — replacement industrial module
Bently Nevada
SKU: 125712-01
In Stock

Can't Find the Part You Need?

We source 100,000+ PLC & DCS spare parts across 20+ brands. Send us your part number and we'll get back to you within 4 hours.

Send an Inquiry →